A Kyoto specialist in diabetes testing equipment for laboratories, clinics and homes; blood glucose self-monitoring is one part, and financials are disclosed only for the group's sales

ARKRAY comes up in any discussion of biosensors because it is a Japanese specialist that has made single-use blood glucose sensors (test strips) and meters, based on an enzyme and an electrode, since the 1970s. According to the company profile on its website, group sales were ¥56.9 billion (fiscal year to October 2025) and the group had 2,091 employees (1 November 2025). The business is described in three layers: instruments for large hospitals, point-of-care testing for smaller hospitals and clinics, and self-monitoring meters for patients, with functional food ingredients on the side. According to FDA documents, the company's glucose test strips (GLUCOCARD W and Assure Titanium) are amperometric and use the enzyme glucose oxidase, and in Assure Titanium the mediator is hexaammineruthenium(III) chloride. That is a typical biosensor. This profile sets out what can be confirmed from official documents and what is not disclosed. No continuous glucose monitoring (CGM) product appears in the documents reviewed.

Sources: ARKRAY's official website (company profile, history, news), FDA public documents and official press releases, used as primary material. Last updated October 2026.

What this article covers
  1. ARKRAY in 30 seconds, and where it stands in biosensors
  2. The logo and how the name is written
  3. Where the company sits in the field
  4. Scale
  5. Resources committed to biosensors
  6. What it has done so far
  7. What comes next
  8. What the company is aiming for in biosensors
  9. Map of partnerships in biosensors
  10. Technologies, products and services
  11. The risks this company carries
  12. Glossary, references and claim-to-source audit

1. ARKRAY in 30 seconds, and where it stands in biosensors

LEGAL NAMEARKRAY, Inc.Founded 1960, incorporated 1963. Headquarters in Nakagyo-ku, Kyoto (moved in March 2025)
LISTINGNot stated in official documentsProbably unlisted (our inference). No securities report found
CATEGORY IN THIS FIELDIn vitro diagnostics & POCT (main)
Diabetes self-monitoring (secondary)
No continuous glucose monitoring product confirmed
SALES (GROUP)¥56.9 billionFiscal year to October 2025. No breakdown by business
EMPLOYEES (GROUP)2,091As of 1 November 2025
MAIN ANALYTES AND TECHNOLOGIESGlucose, HbA1c, urinalysis
dry chemistry
Glucose is measured with an enzyme and an electrode (amperometry)
SELF-MONITORING BRANDGLUCOCARDIn FDA filings the same system sometimes appears with other brand names (such as ReliOn)
COMPANY NOTICE9 March 2026A website selling a non-invasive glucose meter that uses the ARKRAY name is declared unrelated
The one thing to grasp first

ARKRAY is best understood not as "a continuous glucose monitoring company" but as "a maker of diabetes-centered testing instruments and reagents for three places (laboratory, clinic and home), of which self-monitoring meters are one part" Our calculation. The website describes its businesses as for large hospitals and research institutions, for smaller hospitals and clinics, and for patients, but does not disclose sales for each Sourced. What share of group sales comes from self-monitoring meters could not be confirmed either Not yet confirmed.

2. The logo and how the name is written

A note on names: the legal entity is ARKRAY, Inc. (Arkray Kabushiki Kaisha in Japanese). The brand logo is set in lower case ("arkray"). The company was founded as Kyoto Daiichi Kagaku and took its present name in June 2000 (company history). The group has several companies, including ARKRAY Marketing, ARKRAY Factory and ARKRAY Infinity, so the applicant for a product's approval or certification differs from product to product. GLUCOCARD, Assure, ADAMS, AUTION, SPOTCHEM and The Lab are product or brand names, not company names. The logo image was taken from the company's official website.

Official site: https://www.arkray.co.jp/english/

3. Where the company sits in the field

Four types of company involved in biosensors All are "sensor companies", yet the setting, customers and regulatory burden differ widely Diabetes & continuous monitoring In vitro diagnostics & POCT Wearables & consumer devices Materials & components Measure glucose continuously Sell analyzers and reagents Measure in daily life Supply enzymes and electrodes Dexcom / Abbott Medtronic / Senseonics Roche / bioMérieux Siemens Healthineers Apple / Samsung Oura and others Toyobo / Paragraf and others Sensors and clinical data Tied to regulation, payers Installed base of analyzers Tied to test demand, payers Large user base Limited in medical claims Material performance Tied to end-product demand Spans in vitro diagnostics and diabetes self-monitoring; instruments and reagents are the base No continuous glucose monitoring product confirmed; only group sales are disclosed
Fig. 1 The four types of company involved in biosensors, and where ARKRAY sits. The categories are this article's own, and the company names are examples from the companies covered in this series Our calculation. Sales and headcount are from the company profile (whole group).

4. Scale

ARKRAY does not disclose detailed financials. The company profile on its website gives only group sales, headcount and the fiscal-year span (November to October) Sourced.

IndicatorFigureDate and note
Sales (whole group)¥56.9 billionFiscal year to October 2025 (company profile)
Employees (whole group)2,0911 November 2025 (company profile)
Operating profit, net profit, capital, R&D spending, capital expenditureNot disclosedNot in the company profile or brochure
Sales by business (instruments, self-monitoring meters, functional food ingredients)Not disclosedThe business page describes content only

The company history records milestones in sales: ¥10 billion in 1990, ¥20 billion in 1995 and ¥50 billion in 2002. The history does not say whether these were parent-only or consolidated figures Sourced.

A caution

The group is split into sales companies (ARKRAY Marketing, ARKRAY Global Business), manufacturing companies (ARKRAY Factory, ARKRAY Infinity), R&D and software companies and others, with production and sales sites abroad in the United States, the United Kingdom, Ireland, the Philippines, China, Russia and elsewhere (company history and group page). Which company makes and markets which product differs by product (for example, the HbA1c reagent "Sanku HbA1c" is made and marketed by ARKRAY Factory). Whether the company is listed is not stated in official documents. It is probably unlisted, but this article has not confirmed it Not yet confirmed.

5. Resources committed to biosensors

ARKRAY does not disclose R&D spending, capital expenditure or R&D headcount. The table sets out what could be confirmed from the company history and news.

ResourceWhat primary sources confirmCategory
People2,091 employees across the group (1 November 2025). R&D bases include the Kyoto Research Institute (operating from 2011), the Nagasaki Development Center (August 2020), the Osaka Development Center (February 2024), a development site in Xi'an, China (2012) and an R&D base in Singapore (2013) (company history). The number of R&D staff is not disclosedSourced / partly undisclosed
MoneyR&D spending and capital expenditure are not disclosed. Facilities mentioned: a manufacturing base in the Philippines (established 2011; an instrument factory and logistics building completed in January 2016), Pinghu, China (2014), the United Kingdom (2009), the United States (2006), Russia (2013), Ireland (December 2021) and the Konan plant in Shiga (1990)Undisclosed / Sourced (sites)
Acquisitions, investments, alliances, business transfersIn 2004 a business and capital alliance with MC Kenkyusho (MC Institute); in 2007 a joint venture in India with a pharmaceutical company (ARKRAY PIRAMAL Medical); in 2009 an investment in ELITECH France SAS; in 2013 a capital and business alliance with Boditech Med of Korea; in 2015 completion of a business transfer from Span Diagnostics Ltd. to ARKRAY Healthcare Pvt. Ltd. In September 2025 the company agreed to transfer the manufacture and marketing of its HbA1c reagent "Sanku HbA1c" to Shino-Test Corporation (planned for 2026). No amounts are given. On supply, PHC Corporation's materials list ARKRAY, Inc. as the delivery destination (OEM) for a self-monitoring blood glucose system (not mentioned in ARKRAY's documents)Sourced
Universities, research institutions, public fundingJoint research with 14 sites, including Kyoto University, Kindai University and Kyoto Prefectural University of Medicine (identifying pancreatic cancer from blood microRNA; published in the British Journal of Cancer in August 2024). Funding listed for the project as a whole includes ARKRAY research funds, JSPS grants, AMED, the Moonshot program and JST. ARKRAY's share is not disclosed, and no public funding specific to glucose sensor research could be foundSourced / partly not found

Regulatory status (as far as could be confirmed)

For the United States, entries were checked against the FDA 510(k) database (updated 21 September 2026) and decision documents. Thirty-four 510(k) records list ARKRAY (or an affiliate) as applicant. All are 510(k) clearances; none is a PMA approval or De Novo authorization. For Japan, the numbers below are those given in company announcements; they were not cross-checked against the PMDA public database Sourced.

ProductUse (summary of the official document)Category and dateNumber
Assure Titanium Blood Glucose Monitoring SystemA prescription-only system for healthcare professionals that quantifies glucose in fresh fingertip capillary whole blood. Intended for multiple-patient use in endocrinology clinics and nursing or skilled nursing facilities, with single-use auto-disabling lancing devices. Not for screening or diagnosing diabetes, not for acute care or hospital settings, not for neonates. Amperometric510(k) clearance (Dual Track), Class II (21 CFR 862.1345). 23 May 2022K200788
GLUCOCARD W onyx Blood Glucose Monitoring SystemQuantifies glucose in fresh capillary whole blood from the fingertip or palm. For use at home by one person with diabetes to check the effectiveness of a diabetes control program. Not to be shared; not for diagnosing or screening for diabetes or for neonates. Electrochemical, using glucose oxidase510(k) clearance (Special), Class II. 10 April 2019 (applicant Arkray Factory, Inc.)K183306
GLUCOCARD W Blood Glucose Monitoring SystemThe predecessor of the W onyx (the document says the W onyx uses the same test strips and technology)510(k) clearance (Traditional). 16 August 2017K170064
ADAMS A1c HA-8180VAn HbA1c analyzer (product code PDJ). The use statement was not checked here510(k) clearance (Traditional). 29 June 2017K162822
AUTION EYE AI-4510 / AUTION MAX AX-4060A urine particle analysis system / a urinalysis system (laboratory). The use statements were not checked here510(k) clearance. 3 May 2024 / 13 April 2023K232416 / K193514
Rapid Chip BNP-II (name transliterated from Japanese)Measures BNP in plasma or whole blood. Immunochromatography, 120 µL sample, about 10 minutes, measuring range 10 to 800 pg/mL (manufacturer's stated values). Used with the dedicated analyzer Rapidpia IIJapan: in vitro diagnostic reagent, certification number 305ADEZX000580000 (company announcement). On sale from 7 September 2026-
SillHa Kenshin LH-4920 and test paperAn oral-environment measurement system that qualitatively measures hemoglobin in mouth-rinse liquid. The company states it supports diagnosis and does not make a definitive diagnosisJapan: the instrument is a Class I notified device (notification number 25B1X00001000070); the test paper is an in vitro diagnostic reagent (certification number 308AAEZX00014000) (company announcement). On sale from 15 July 2026-
GLUCOCARD Prime / Plus Care (Japan)Self-monitoring blood glucose meters. The company states conformity with ISO 15197:2013. The product page gives no approval or certification number and refers readers to the PMDA site for the latestJapan: number not confirmed-

The status of each product under the EU In Vitro Diagnostic Regulation (IVDR) could not be confirmed here Not yet confirmed. The FDA recall database has six records under ARKRAY's U.S. entities between 2007 and 2019 (titles and dates only; for example a 2007 Hypoguard blood glucose monitoring system, 2015 SPOTCHEM II test strips and 2019 software for the AUTION HYBRID) Sourced. For regulatory categories and how they differ from home use, see our explainer on medical device approval categories and home use.

A materials engineer's view: the enzyme and electrode that remain visible despite the silence

Even where financials are undisclosed, how materials are used in glucose measurement can be confirmed from FDA documents and company announcements. In the Assure Titanium strip, blood is drawn in by capillary action at the tip, where glucose oxidase (GOD) and hexaammineruthenium(III) chloride react to form ruthenium(II); the current from oxidizing it at the electrode is read by the meter and converted to a glucose value (FDA document). The laboratory glucose analyzer ADAMS Glucose GA-1180 likewise uses an enzyme membrane with immobilized GOD and a hydrogen peroxide electrode, measured by amperometry (company announcement) Sourced. From a materials standpoint, the stability of the enzyme, a mediator that is not disturbed by other substances in blood, the area and reproducibility of the electrode, and a flow path that draws in a fixed volume bear on accuracy in whole blood Not yet confirmed. However, the electrode materials, enzyme modifications and layer structure of the strip are not given in the documents retrieved. See our explainers on enzyme and electrode interface materials and on electrochemical sensors.

6. What it has done so far

WhenEventMeaning
June 1960Its founder established Kyoto Daiichi Kagaku in Kyoto, beginning with optical parts for infrared instrumentsStarted from precision parts for measuring instruments
1970Developed a simple blood glucose meter ("Aitone") and a rapid blood analyzer; won prizes at European trade fairs in 1974 and 1975The company records blood glucose meters as far back as 1970
1979Developed a continuous blood glucose measuring device ("Glucose Monitor") (company history)Not the same as today's wearable CGM; no further detail could be confirmed
1981Developed the world's first automated glycohemoglobin fractionation analyzer (AUTO A1c)Automation of HbA1c testing
1991Developed the simple self-monitoring blood glucose system "GLUCOCARD"Origin of the current brand
1992Developed an automated glycated albumin analyzer and proposed glycated albumin as a new index for diabetes managementA glycemic index other than HbA1c
1995Introduced the corporate brand "ARKRAY"; lent blood glucose meters free of charge after the Great Hanshin earthquakeCompany statement
2004-2013Alliance with MC Kenkyusho (2004), an Indian joint venture (2007), an investment in ELITECH France (2009), a capital and business alliance with Boditech Med (2013)Alliances and overseas expansion
May 2008Began selling self-monitoring blood glucose meters for diabetes patients under its own sales organization in JapanDirect sales to the home market
June 2020Developed the GLUCOCARD Prime self-monitoring meter (the company states conformity with ISO 15197:2013)A current main model
23 May 2022Assure Titanium received FDA 510(k) clearance (prescription, for healthcare professionals)A blood glucose meter for healthcare professionals
January-March 2024Launched a COVID-19 and influenza antigen test kit (about 5 minutes) and updated its glucose analyzer to ADAMS Glucose GA-1180Updates to laboratory and rapid-test lines
28 August 2024With Kyoto University and others, published a blood microRNA model for identifying pancreatic cancerA research result; commercialization has not been announced
March 2025Moved its headquarters within Nakagyo-ku, Kyoto; set up a sales base in Thailand-
5 September 2025Agreed to transfer the manufacture and marketing of the HbA1c reagent "Sanku HbA1c" to Shino-TestA move to let go of one HbA1c reagent business
9 March 2026Warned that websites selling a non-invasive glucose meter under its name have nothing to do with ARKRAYA company statement. No report that the company has commercialized non-invasive glucose measurement could be found
15 July 2026Launched the oral-environment measurement system SillHa Kenshin LH-4920A new area beyond glucose
4 September 2026Announced Rapid Chip BNP-II (on sale 7 September)An addition to rapid tests usable near the patient

7. What comes next

TRANSFER OF SANKU HbA1cPlanned for 2026To Shino-Test; the company says details will follow once decided
RAPID CHIP BNP-IIOn sale 7 September 2026Whole blood or plasma, about 10 minutes (manufacturer's stated value)
SILLHA KENSHINOn sale 15 July 2026Listed as a reagent envisaged for a Ministry of Health, Labour and Welfare dental-screening pilot
MEDIUM-TERM NUMERICAL TARGETSNot foundNo targets for sales, profit or investment appear in the official documents

The primary sources also describe the following plans Not yet confirmed.

  • For the microRNA pancreatic-cancer model, the August 2024 announcement says the partners plan to continue R&D toward practical use, including validation in high-risk groups. No timing for a product is given
  • The president's 2026 New Year address (summary) sets out the "three thoroughnesses" as guiding principles for the year and more reskilling for AI use; it contains no numerical targets or new-product plans
What could not be confirmed

Operating profit, R&D spending, capital expenditure and sales by business / whether the company is listed / the share of self-monitoring meters in sales and unit volumes / approval or certification numbers in Japan for each product / the status under the IVDR / whether the company has any continuous glucose monitoring product or development / the detailed materials and structure of the sensor strips. None appears in the official documents retrieved.

8. What the company is aiming for in biosensors

This section separates what the company says it is aiming for from what this article reads into the record. Inference marks interpretation drawn by this article from primary sources.

What can be readPrimary source behind itCategory
It aims at testing that links three places: laboratory, clinic and homeThe business page lists products in three layers (large hospitals, smaller hospitals and clinics, patients) and says it also provides data management systemsSourced (company explanation)
It is extending rapid tests (immunochromatography)The COVID-19 and influenza antigen kit (2024) and Rapid Chip BNP-II (2026)Sourced
It is widening beyond diabetes (oral health, cancer, veterinary care)SillHa (oral environment), the microRNA pancreatic-cancer research, and the veterinary brand thinkaSourced
It is letting go of an HbA1c reagent while focusing on instruments and rapid testsThe agreement to transfer Sanku HbA1c; new instruments and rapid tests launched around the same timeSourced (transfer) / Inference (where it is focusing)
It has probably not entered continuous glucose monitoring (CGM)No CGM appears in the official product information or news. It states that a non-invasive glucose meter using its name is unrelatedInference (an absence read as meaning; whether development exists is unknown)
One inference, explained in more detail

The reading that "ARKRAY has probably not entered CGM" rests on the absence of CGM from the official product list and news. The website's product information lists large instruments, small instruments, health screening, healthcare, diabetes treatment support (self-monitoring meters, lancing devices and management apps) and veterinary care, but no wearable continuous measurement product Sourced. The March 2026 notice also says that a non-invasive glucose meter using the company name has "nothing to do with" it. However, that does not show that no development or partnership exists outside the website. This article confirmed only the absence Not yet confirmed.

9. Map of partnerships in biosensors

Investments, joint venture, research and transfer around ARKRAY Only relationships stated in the company history or news; no press-based relationships ARKRAY Boditech Med (Korea) Capital alliance (2013) ELITECH France Investment (2009) MC Kenkyusho Business and capital tie (2004) ARKRAY PIRAMAL Medical Joint venture in India (2007) Shino-Test HbA1c reagent (agreed) Kyoto Univ. and 13 sites Pancreatic cancer miRNA (2024) PHC Corporation Supplies meters (OEM) ARKRAY's own documents name no supplier of sensor parts Investment / capital alliance Business transfer Joint venture / joint research Supply
Fig. 2 Investments, a joint venture, joint research and a business transfer around ARKRAY. Sources: the company history, the official announcements of 28 August 2024 and 5 September 2025, and the 2026 company overview of PHC Holdings. Dotted lines show investments and capital alliances, dashed lines a business transfer, solid navy lines a joint venture or joint research, and orange a supply relationship. Only relationships stated in official documents are shown (the PHC link is stated in PHC's document, not in ARKRAY's). The 2015 business transfer from Span Diagnostics is left out to keep the figure simple (see the text).

The relationships that can be confirmed are investments and capital alliances, a joint venture, a business transfer, joint research and a supply link from PHC. PHC Holdings' 2026 company overview lists, among the OEM supply that PHC Corporation provides to domestic partners, a self-monitoring blood glucose system with ARKRAY, Inc. as the delivery destination Sourced. ARKRAY's own documents do not mention this supply, so which model it covers, and for which market, could not be confirmed (in FDA filings, GLUCOCARD W and others are filed in the name of Arkray Factory, Inc.) Not yet confirmed. No other supplier of test strips or parts is named in ARKRAY's documents. In FDA filings, the same blood glucose system is listed under more than one brand, such as "GLUCOCARD 01" and "ReliOn Confirm", but the sales relationship behind that could not be confirmed from the official documents retrieved Not yet confirmed.

10. Technologies, products and services

The product information on the company website is divided into large instruments, small instruments, health screening, healthcare, diabetes treatment support and veterinary care. The table focuses on those closest to biosensors. All figures are manufacturer's stated values; test conditions and editions differ, so no ranking is made between products, or against other companies' products Sourced.

CategoryWhat the official sources sayComment
Home: GLUCOCARD self-monitoring metersGLUCOCARD Prime: about 0.6 µL of blood; measurement time 5.5 seconds (G sensor) or 7 seconds (Prime sensor) after the drop is detected. The company states conformity with ISO 15197:2013. Also GLUCOCARD Plus Care, the "Natureret" lancing device and the smartphone app "Smart e-SMBG" with a cloud serviceManufacturer's stated values. Electrochemical (FDA documents). How to read an individual's reading is a matter for their healthcare professional
For healthcare professionals: Assure TitaniumA prescription blood glucose meter for multiple-patient use in endocrinology clinics and nursing facilities (U.S.). Amperometric, with GOD and hexaammineruthenium(III) (FDA document)A different use category from a self-monitoring meter for home
Laboratory: ADAMS seriesHbA1c analyzers (HA-8190V, HA-8380 and others) and glucose analyzers. ADAMS Glucose GA-1180: whole blood, serum, plasma and urine; amperometry with an enzyme membrane carrying immobilized GOD and a hydrogen peroxide electrode; about 30 µL of sample; up to 156 measurements an hourManufacturer's stated values. For large hospitals and laboratories
Laboratory and clinic: urine and dry chemistryThe AUTION series (urinalysis), SPOTCHEM (dry-chemistry blood biochemistry) and The Lab series (HbA1c, protein, dry chemistry)The company history presents dry chemistry, reagents on dry test strips, as a feature of the lineup
Rapid testsA COVID-19 and influenza antigen kit (about 5 minutes), Rapid Chip BNP-II (about 10 minutes, immunochromatography), SPOTCHEM FLORA (a mobile immunofluorescence analyzer) and the lactate meter Lactate Pro 2Immunochromatography uses antibodies; it is not an electrochemical sensor
Oral, veterinary and food ingredientsThe oral-environment system SillHa (hemoglobin in mouth rinse), the veterinary brand thinka (glucose meters and urine analyzers for dogs and cats, Vcheck V200 and others) and functional food ingredients (anti-glycation and others)Areas beyond diabetes
A materials engineer's view: measuring glucose in whole blood with a small strip

Electrochemical measurement of glucose in whole blood stacks several materials problems: the stability of the enzyme (GOD and others), the choice of mediator so that other substances in blood do not interfere, the area and reproducibility of the electrode, and a capillary flow path that draws in a fixed volume of blood. The FDA document records that Assure Titanium was evaluated across a claimed hematocrit range of 10 to 70% and that the effect of interfering substances was assessed Sourced. How a strip's design keeps the effects of blood thickness (hematocrit) and co-existing drugs and substances small is the central materials question for this kind of device Not yet confirmed. However, the electrode materials, the type and immobilization of the enzyme, and the layer structure of the strip are not given in the documents retrieved. The laboratory GA-1180 is stated to use "an enzyme membrane with immobilized GOD and a hydrogen peroxide electrode", which shows that enzyme immobilization technology underlies the product.

11. The risks this company carries

RiskDetailCategory
Limited disclosureOperating profit, R&D spending, capital expenditure and sales by business are all undisclosed, so the scale and changes of the business are hard to check from outsideNot yet confirmed
Reshuffling of businessesAn agreement to transfer the HbA1c reagent "Sanku HbA1c" to Shino-Test (September 2025; planned for 2026): the company is letting go of part of its core diabetes testing lineupSourced
Misuse of the company nameIn March 2026 it was reported that social media was directing people to sites selling a non-invasive glucose meter under the ARKRAY name; the company said these have nothing to do with itSourced (company announcement)
Relationship to continuous glucose monitoringThe position of self-monitoring meters can change as continuous monitoring spreads. Whether ARKRAY has a continuous monitoring product could not be confirmedInference
Restrictions on useThe U.S. Assure Titanium is prescription-only and its use does not include acute care, hospitals or neonates. GLUCOCARD W onyx is not for diagnosis or screening eitherSourced (FDA documents)
FDA recall recordsThe FDA recall database has six records under ARKRAY's U.S. entities between 2007 and 2019 (facts and dates only; content by title)Sourced
Results still at the research stageThe microRNA pancreatic-cancer model is at the research stage and no commercialization date has been given. It is not for diagnosis or screeningSourced (company explanation)
Confirming the status in JapanThe official page for the self-monitoring meters gives no approval or certification number. A check against the PMDA database was not done hereNot yet confirmed

12. Glossary

Self-monitoring of blood glucose (SMBG)
Measuring one's own blood glucose from a small blood sample, usually from a fingertip, with a meter and a single-use test strip (sensor). How to read results and use them in treatment depends on the instructions of a healthcare professional.
HbA1c (glycohemoglobin)
Hemoglobin in red blood cells to which glucose has bound. A test item that reflects blood glucose over roughly the previous one to two months.
Glycated albumin
Albumin in the blood to which glucose has bound. A test item that reflects blood glucose over a shorter period than HbA1c.
Amperometry
A method in which a voltage is applied to an electrode and concentration is derived from the current that flows in the reaction. Widely used in glucose meters.
Mediator
A substance that carries electrons between the enzyme and the electrode. In Assure Titanium it is hexaammineruthenium(III) (FDA document).
Dry chemistry
A format in which reagents are carried on a dry strip or film, so that blood and other samples can be tested without liquid reagents.
Immunochromatography
A method that uses antibodies to capture and detect a target substance as the sample flows along a test strip.
BNP
Brain natriuretic peptide, a protein measured in blood in connection with strain on the heart. How to read the result is a matter for healthcare professionals.
ISO 15197
The international standard for the performance of blood glucose monitoring systems. ARKRAY states conformity with the 2013 edition.
510(k) clearance
The U.S. FDA route for devices found substantially equivalent to a device already on the market. Distinct from PMA approval and De Novo authorization. "Dual Track" means a 510(k) filed together with a CLIA waiver application.
In vitro diagnostic reagent (Japan)
A category under Japanese law for reagents used to test samples such as blood outside the body. The instrument is regulated separately as a medical device.
Concept image: a handheld glucose meter in a clinic room beside a benchtop analyzer in a laboratory, with an enlarged view of the inside of a test strip
Fig. 3 Concept image of diabetes testing instruments (AI-generated concept; it does not depict an actual product or facility). A handheld glucose meter used in a clinic room and a benchtop analyzer in a laboratory are shown side by side, with an enlarged view of the inside of a single-use test strip.

13. References

  1. ARKRAY Company profile (in Japanese). Company name, representative, address, founding and incorporation dates, sales (whole group, fiscal year to October 2025) and headcount (whole group, 1 November 2025). https://www.arkray.co.jp/japanese/about/profile.html
  2. ARKRAY Corporate Outline (English). Sales JPY 56.9 billion (All ARKRAY group) as of October 2025; 2,091 employees; fiscal year. https://www.arkray.co.jp/english/about/profile.html
  3. ARKRAY Business overview (in Japanese). Medical testing systems (for large hospitals and research institutions, for smaller hospitals and clinics, for patients) and functional food ingredients. https://www.arkray.co.jp/japanese/about/business.html
  4. ARKRAY ARKRAY Group (in Japanese). The sales, manufacturing, logistics and software companies of the group. https://www.arkray.co.jp/japanese/about/group02.html
  5. ARKRAY History, 1960s (in Japanese). Founding, incorporation and early products. https://www.arkray.co.jp/japanese/about/history1960.html
  6. ARKRAY History, 1970s (in Japanese). The simple blood glucose meter "Aitone", the Glucose Monitor and prizes. https://www.arkray.co.jp/japanese/about/history1970.html
  7. ARKRAY History, 1980s (in Japanese). The world's first automated glycohemoglobin fractionation analyzer (AUTO A1c) and others. https://www.arkray.co.jp/japanese/about/history1980.html
  8. ARKRAY History, 1990s (in Japanese). GLUCOCARD, glycated albumin, sales milestones and brand introduction. https://www.arkray.co.jp/japanese/about/history1990.html
  9. ARKRAY History, 2000s (in Japanese). Name change, overseas expansion, alliances, investments, the joint venture and the start of direct sales. https://www.arkray.co.jp/japanese/about/history2000.html
  10. ARKRAY History, 2010s (in Japanese). Research and manufacturing bases, the alliance with Boditech Med, the business transfer from Span Diagnostics and the product timeline. https://www.arkray.co.jp/japanese/about/history2010.html
  11. ARKRAY History, 2020s (in Japanese). The Nagasaki and Osaka development centers, overseas bases, the headquarters move and GLUCOCARD Prime. https://www.arkray.co.jp/japanese/about/history2020.html
  12. ARKRAY News 2026, What's New (in Japanese). The list of items including Rapid Chip BNP-II, SillHa Kenshin and the notice about name misuse. https://www.arkray.co.jp/japanese/news/2026/index.html
  13. ARKRAY Announcement "Rapid Chip BNP-II launched: BNP measured from whole blood or plasma in about 10 minutes" (4 September 2026; in Japanese). Measurement principle, sample volume, range and certification number. https://www.arkray.co.jp/japanese/news/into/info20260904_jp_jp.html
  14. ARKRAY Announcement on the oral-environment measurement system "SillHa Kenshin LH-4920" (30 September 2026; in Japanese). Notification and certification numbers and the listing in the Ministry of Health, Labour and Welfare pilot project. https://www.arkray.co.jp/japanese/news/press/release20260930_jp_jp.html
  15. ARKRAY Important notice on non-invasive blood glucose meters that use the ARKRAY name (9 March 2026; in Japanese). https://www.arkray.co.jp/japanese/news/into/20260306_02.html
  16. ARKRAY Announcement on the transfer of the manufacture and marketing of the in vitro diagnostic reagent "Sanku HbA1c" (5 September 2025; in Japanese). https://www.arkray.co.jp/japanese/news/into/20250905.html
  17. ARKRAY / Kyoto University and others Announcement "Research toward a pancreatic cancer diagnostic using blood microRNA" (28 August 2024; in Japanese). The 14 sites, funding and future plans. https://www.arkray.co.jp/japanese/news/press/release_20240828_jp_jp.html
  18. ARKRAY Announcement "Glucose analyzer model change: ADAMS Glucose GA-1180" (22 March 2024; in Japanese). Measurement principle and specifications. https://www.arkray.co.jp/japanese/news/press/release_20240322_jp_jp.html
  19. ARKRAY Summary of the 2026 New Year address (5 January 2026; in Japanese). https://www.arkray.co.jp/japanese/news/press/release20260105_jp_jp.html
  20. ARKRAY GLUCOCARD Prime (product page for the self-monitoring meter; in Japanese). ISO 15197:2013 conformity, required blood volume and measurement time; manufacturer's stated values. https://www.arkray.co.jp/smbg/prime/index.html
  21. U.S. Food and Drug Administration 510(k) K200788 "Assure Titanium Blood Glucose Monitoring System": clearance letter and summary. Use and measurement principle. https://www.accessdata.fda.gov/cdrh_docs/pdf20/K200788.pdf
  22. U.S. Food and Drug Administration 510(k) K183306 "GLUCOCARD W onyx Blood Glucose Monitoring System": clearance letter and summary (10 April 2019). https://www.accessdata.fda.gov/cdrh_docs/pdf18/K183306.pdf
  23. U.S. Food and Drug Administration (openFDA) 510(k) database API (records with ARKRAY in the applicant name; the database was last updated on 21 September 2026). Registration details for K170064, K162822, K232416, K193514 and others. https://api.fda.gov/device/510k.json?search=applicant:ARKRAY&limit=40
  24. U.S. Food and Drug Administration (openFDA) Medical device recall API (records with Arkray in the recalling firm name). https://api.fda.gov/device/recall.json?search=recalling_firm:Arkray&limit=20
  25. PHC Holdings PHC Group Company Overview (presentation issued May 2026). Lists ARKRAY, Inc. as the delivery destination of a self-monitoring blood glucose system under its diabetes-management OEM partnerships (page 15). https://www.phchd.com/jp/~/Media/phchd/about/PHC_Group_Overview_Presentation_Slide.pdf
  26. British Journal of Cancer Kawai M, et al. Early detection of pancreatic cancer by comprehensive serum miRNA sequencing with automated machine learning. Br J Cancer 2024; 131: 1158-1168. (DOI, verified through Crossref.) https://doi.org/10.1038/s41416-024-02794-5

14. Claim-to-source audit

Claim in the textCategorySource
Legal name, representative, address, founding in 1960 and incorporation in 1963, fiscal year (November to October)SourcedReference 1 https://www.arkray.co.jp/japanese/about/profile.html Reference 2 https://www.arkray.co.jp/english/about/profile.html
Sales of ¥56.9 billion (whole group, fiscal year to October 2025) and 2,091 employees (1 November 2025)SourcedReference 1 https://www.arkray.co.jp/japanese/about/profile.html Reference 2 https://www.arkray.co.jp/english/about/profile.html
No disclosure of operating profit, R&D spending, capital expenditure or sales by businessNot yet confirmedNot in References 1 to 3. Undisclosed; not estimated in this article Reference 1 https://www.arkray.co.jp/japanese/about/profile.html Reference 2 https://www.arkray.co.jp/english/about/profile.html Reference 3 https://www.arkray.co.jp/japanese/about/business.html
Whether the company is listed (not stated in official documents)Not yet confirmedNot confirmed here. It appears to be unlisted, but that is an inference and we do not claim it Reference 1 https://www.arkray.co.jp/japanese/about/profile.html Reference 2 https://www.arkray.co.jp/english/about/profile.html
The three layers of business (large hospitals and research institutions, smaller hospitals and clinics, patients) and functional food ingredientsSourcedReference 3 https://www.arkray.co.jp/japanese/about/business.html
Sales milestones (¥10 billion in 1990, ¥20 billion in 1995, ¥50 billion in 2002)SourcedReference 8 https://www.arkray.co.jp/japanese/about/history1990.html Reference 9 https://www.arkray.co.jp/japanese/about/history2000.html
The division of roles among group companies (sales, manufacturing, logistics, software and others)SourcedReference 4 https://www.arkray.co.jp/japanese/about/group02.html
The name change (June 2000) and the original name (Kyoto Daiichi Kagaku)SourcedReference 5 https://www.arkray.co.jp/japanese/about/history1960.html Reference 9 https://www.arkray.co.jp/japanese/about/history2000.html
The simple blood glucose meter "Aitone" in 1970, prizes in 1974-75, the Glucose Monitor in 1979SourcedReference 6 https://www.arkray.co.jp/japanese/about/history1970.html
AUTO A1c in 1981, GLUCOCARD in 1991, glycated albumin in 1992, brand introduction in 1995SourcedReference 7 https://www.arkray.co.jp/japanese/about/history1980.html Reference 8 https://www.arkray.co.jp/japanese/about/history1990.html
MC Kenkyusho in 2004, the Indian joint venture in 2007, ELITECH France in 2009, direct sales from 2008SourcedReference 9 https://www.arkray.co.jp/japanese/about/history2000.html
Boditech Med in 2013, the business transfer from Span Diagnostics in 2015, research and manufacturing bases (Kyoto Research Institute, Xi'an, Singapore, the Philippines and others)SourcedReference 10 https://www.arkray.co.jp/japanese/about/history2010.html
The Nagasaki and Osaka development centers, overseas bases such as Ireland, the March 2025 headquarters move, GLUCOCARD Prime in 2020SourcedReference 11 https://www.arkray.co.jp/japanese/about/history2020.html
The agreement to transfer Sanku HbA1c to Shino-Test (5 September 2025), planned for 2026SourcedReference 16 https://www.arkray.co.jp/japanese/news/into/20250905.html
Joint research with Kyoto University and 13 other sites (blood microRNA and pancreatic cancer), the funding and the publicationSourcedReference 17 https://www.arkray.co.jp/japanese/news/press/release_20240828_jp_jp.html Reference 26 https://doi.org/10.1038/s41416-024-02794-5
Public funding specific to glucose sensor researchNot yet confirmedNot in Reference 17. Not found. We do not claim that none exists Reference 17 https://www.arkray.co.jp/japanese/news/press/release_20240828_jp_jp.html
PHC Corporation lists ARKRAY, Inc. as the delivery destination (OEM) of a self-monitoring blood glucose systemSourcedStated in PHC's document; not in ARKRAY's documents, and the model concerned cannot be confirmed. Reference 25 https://www.phchd.com/jp/~/Media/phchd/about/PHC_Group_Overview_Presentation_Slide.pdf
Names of suppliers of test strips and parts (ARKRAY's own documents)Not yet confirmedNot in ARKRAY's documents. Not found Reference 1 https://www.arkray.co.jp/japanese/about/profile.html Reference 3 https://www.arkray.co.jp/japanese/about/business.html
Rapid Chip BNP-II specifications (immunochromatography, 120 µL, about 10 minutes, 10 to 800 pg/mL), certification number 305ADEZX000580000, on sale 7 September 2026SourcedManufacturer's stated values and company announcement. Reference 13 https://www.arkray.co.jp/japanese/news/into/info20260904_jp_jp.html
SillHa Kenshin LH-4920 (notification number 25B1X00001000070, Class I) and test paper (certification number 308AAEZX00014000), on sale 15 July 2026SourcedReference 14 https://www.arkray.co.jp/japanese/news/press/release20260930_jp_jp.html
The notice that a non-invasive glucose meter using the company name is unrelated (9 March 2026)SourcedCompany announcement. Reference 15 https://www.arkray.co.jp/japanese/news/into/20260306_02.html
ADAMS Glucose GA-1180 specifications (immobilized-GOD enzyme membrane and hydrogen peroxide electrode, about 30 µL, up to 156 measurements an hour)SourcedManufacturer's stated values. Reference 18 https://www.arkray.co.jp/japanese/news/press/release_20240322_jp_jp.html
GLUCOCARD Prime specifications (about 0.6 µL, 5.5 or 7 seconds) and the ISO 15197:2013 conformity claimSourcedManufacturer's stated values (product page). Reference 20 https://www.arkray.co.jp/smbg/prime/index.html
FDA 510(k) clearance of Assure Titanium (K200788, 23 May 2022, Dual Track, prescription use, multiple-patient use) and its measurement principle (GOD, hexaammineruthenium)SourcedReference 21 https://www.accessdata.fda.gov/cdrh_docs/pdf20/K200788.pdf
FDA 510(k) clearance of GLUCOCARD W onyx (K183306, 10 April 2019), single-person home use, electrochemical with glucose oxidaseSourcedReference 22 https://www.accessdata.fda.gov/cdrh_docs/pdf18/K183306.pdf
Registration details of GLUCOCARD W (K170064), ADAMS A1c HA-8180V (K162822), AUTION EYE (K232416) and AUTION MAX (K193514)SourcedDatabase registration details only; use statements not checked. Reference 23 https://api.fda.gov/device/510k.json?search=applicant:ARKRAY&limit=40
Thirty-four FDA 510(k) records listing ARKRAY as applicantSourcedOur own search. Reference 23 https://api.fda.gov/device/510k.json?search=applicant:ARKRAY&limit=40
Six FDA recall records (2007-2019)SourcedTitles and dates only; no evaluation of the content. Reference 24 https://api.fda.gov/device/recall.json?search=recalling_firm:Arkray&limit=20
Approval or certification numbers in Japan for self-monitoring meters, and status under the IVDRNot yet confirmedNot in the documents retrieved. Not confirmed Reference 20 https://www.arkray.co.jp/smbg/prime/index.html
The content of the 2026 New Year address (guiding principles, use of AI)SourcedIt contains no numerical targets. Reference 19 https://www.arkray.co.jp/japanese/news/press/release20260105_jp_jp.html
The reading that the company has probably not entered CGMInferenceThis article's interpretation. It confirms only the absence of CGM; it does not show that no development or partnership exists. Reference 12 https://www.arkray.co.jp/japanese/news/2026/index.html Reference 3 https://www.arkray.co.jp/japanese/about/business.html
The reading that it is letting go of an HbA1c reagent while focusing on instruments and rapid testsInferenceThis article's interpretation. Reference 16 https://www.arkray.co.jp/japanese/news/into/20250905.html Reference 13 https://www.arkray.co.jp/japanese/news/into/info20260904_jp_jp.html
Materials demands of the enzyme, mediator and electrodeInferenceThis article's reading of the FDA document and the company announcement (sourced) into materials requirements. Electrode materials and enzyme immobilization are not disclosed. Reference 21 https://www.accessdata.fda.gov/cdrh_docs/pdf20/K200788.pdf Reference 18 https://www.arkray.co.jp/japanese/news/press/release_20240322_jp_jp.html
The four types of company (diabetes and continuous monitoring / in vitro diagnostics and POCT / wearables and consumer devices / materials and components) and the example company namesOur calculationOur own classification. Company names are examples from the companies covered in this series
The framing "not a CGM company but a maker of testing instruments and reagents for three places"Our calculationOur own framing, drawn from the business overview (Reference 3).

Last updated 4 October 2026 / Troy Technical
Every figure in this article comes from ARKRAY's website and official announcements and from FDA public documents. No research-firm estimates or press-based figures have been used. Passages marked "Inference" are this article's interpretation of primary sources, not statements made by the company. ARKRAY does not state in official documents whether it is listed or give detailed financials, so these are recorded as "not disclosed" or "not confirmed".