MENU

U.S. Food and Drug Administration (FDA) | Institution Profile

← Back to Biosensors & POCT guides

INSTITUTION PROFILE / BIOSENSORS

U.S. Food and Drug Administration (FDA)
The regulator at the door of the U.S. market for medical and diagnostic devices

The FDA is a U.S. federal agency, and medical devices fall to its Center for Devices and Radiological Health (CDRH). Biosensor products such as blood glucose meters and continuous glucose monitors (CGMs) must pass one of three premarket routes (510(k), De Novo or PMA) before they are sold in the United States, and they remain under FDA oversight of registration, quality systems and adverse-event reporting afterwards. The FDA does not write technical standards itself; it formally recognises standards written by others and uses them in its reviews. This profile looks at one question only: how much influence the FDA has over biosensors. It contains no advice on how to use any product or on any reader's personal health.

Sources: the CDRH Annual Report 2025, the FY2025 MDUFA performance report to Congress, the Code of Federal Regulations (21 CFR), the Federal Register, FDA's review databases (510(k), De Novo, PMA, recognised standards) and FDA guidance documents. Last updated October 2026.

Conceptual image of the institution's biosensor-related work
Conceptual image (AI-generated).Conceptual scene of reviewing CGM technical documents and performance data; not actual FDA facilities, staff, or review records.
What this article covers
  1. The FDA in 30 seconds
  2. What kind of body it is: the four types of influence
  3. What it does for biosensors
  4. How far its influence reaches (powers and geography)
  5. Companies and organisations involved
  6. Outlook
  7. Glossary, references and claim-to-source audit

1. The FDA in 30 seconds

FULL NAMEU.S. Food and Drug Administration (FDA)
Center for Devices and Radiological Health (CDRH)
CDRH is the FDA centre responsible for medical devices
COUNTRYUnited StatesLocated in Silver Spring, Maryland (address on the FDA website)
TYPE OF BODYFederal regulatory agencyPart of the Department of Health and Human Services (HHS)
HISTORYCDRH: "more than 40 years"The CDRH annual report's wording. This profile does not cover the FDA's founding year
STAFFFDA-wide: 19,687 FTEFull-time equivalents in FY2024. CDRH's total headcount could not be confirmed in official documents
SCALE (CDRH)21,780 submissionsMedical device submissions received in 2025, and 25,530 registered firms (the annual report's figures)
ROLE IN BIOSENSORSPremarket review and postmarket oversight510(k), De Novo, PMA, registration, quality systems and the classification of in vitro diagnostic devices
REACHEvery manufacturer selling in the U.S.Including overseas companies. It does not reach other countries' rules
The one thing to grasp first

The FDA's "clearance" (510(k)), De Novo "grant" and PMA "approval" are three separate systems. The FDA itself calls a device found substantially equivalent through 510(k) "cleared", and uses "approval" for PMA Sourced. So saying simply that "the FDA approved" a product does not tell you which route it took. The second point is that the FDA's decision covers only whether a device may be sold in the United States. Selling in Japan or the EU requires separate procedures under each system (section 4).

2. What kind of body it is: the four types of influence

The "institutions" that appear in articles on biosensors (medical devices and in vitro diagnostics) do not make products the way companies do. They can be sorted into four types by the route through which they influence the industry. The FDA is a "policy and regulation" body.

Four types of institution that shape biosensors Institutions make no products themselves; they differ in how they influence the industry Funding Policy & regulation Standards Convening Allocates R&D money Review and oversight Test methods, specs Guidelines, journals Research funders FDA / MHLW / EC ISO / CLSI ADA / ACS / WHO What to research What may be sold How to measure What gets recommended Reach: its own budget Reach: that market Reach: those who adopt Reach: members, readers The FDA is a regulator: it governs devices sold in the U.S., not other countries' rules The same biosensor is touched very differently depending on the type of institution
Fig. 1 Four types of institution involved in biosensors, and where the FDA sits. The classification and the examples are our own, drawn from the institutions covered in this series Our calculation. EC: European Commission; MHLW: Japan's Ministry of Health, Labour and Welfare. The FDA does not write standards; it recognises standards written by others for use in its reviews, so it is not placed under "Standards".

3. What it does for biosensors

FDA device regulation sorts devices into Class I, II and III by risk, with controls tightening as the class rises. There are three main premarket routes, and blood glucose meters and CGMs have gone through one or another of them Sourced.

RouteWho it is forFDA's decision and review goalAn example on record in FDA databases
510(k)
Premarket notification
Devices that can show "substantial equivalence" to a legally marketed predicate. Mainly Class I and IIAn order finding substantial equivalence is called "cleared". The MDUFA V goal is 95% of decisions within 90 FDA daysStelo Glucose Biosensor System (Dexcom), K234070, found substantially equivalent on 5 March 2024. Product code SAF (an over-the-counter [OTC] iCGM for people not using insulin)
De NovoNew types of device with no predicate, at low to moderate riskWhen the request is "granted", a new classification (Class I or II) is created and later 510(k) filers can use the device as a predicate. The goal is 70 to 90% within 150 FDA daysDexcom G6 (Dexcom), DEN170088, received 8 December 2017 and granted on 27 March 2018. Classified under 21 CFR 862.1355
PMA
Premarket approval
The highest-risk devices, Class III"Approval" follows when there is sufficient scientific evidence. The goal is 90% within 180 FDA days (where no advisory panel input is used)Eversense CGM System (Senseonics), P160048, approved on 21 June 2018 (an implantable CGM)

Note: "FDA days" are the calendar days a submission is under review, counted from acceptance (510(k), De Novo) or filing (PMA), as defined in the MDUFA performance report. Review goals are targets agreed under MDUFA V, not guarantees. The examples show review outcomes only; they do not rank products.

How CGMs are classified, and the performance requirements the FDA wrote

Among CGMs, the "integrated continuous glucose monitoring system" (iCGM), designed to work with smartphones, insulin pumps and other connected devices, is defined in 21 CFR 862.1355 as Class II with special controls Sourced. The special controls spell out the accuracy a clinical study must show. For the adult population, for example, in the 70 to 180 mg/dL range the lower one-sided 95% confidence bound on "the share of readings within ±15%" must exceed 70%, and on "the share within ±40%" must exceed 99% Sourced. These are regulatory requirements that manufacturers must demonstrate in a submission; they are not guidance on how to read any individual product's measurements.

A materials engineer's view: the requirements are written for the whole sensor

The requirements in 862.1355 are framed not around electrodes or enzyme membranes but around the accuracy of the sensor as a whole, consistency across the wear period, resistance to interfering substances, and measures that stop a sensor being used past its stated life Sourced. For a materials supplier, choosing materials and designing membranes are means of meeting those whole-system requirements; the FDA does not dictate material compositions directly. Whether a change of material needs a new review depends on the nature of the change and the device class, so it has to be checked case by case (this profile does not make that judgement).

In vitro diagnostics, home use, standards and quality

TopicWhat the primary sources sayCategory
Responsible officeWithin CDRH's Office of Product Evaluation and Quality (OPEQ), the Office of In Vitro Diagnostics (OHT7) is responsible for the total product life cycle of in vitro diagnostics. Its Division of Chemistry and Toxicology Devices (DCTD) is described as covering clinical chemistry devices, including diabetes-related onesSourced
CLIA categorisationThe FDA sorts laboratory tests by complexity under CLIA (the U.S. clinical laboratory law): waived, moderate or high complexity. A manufacturer can ask the FDA to recategorise a moderate-complexity test as waived (CLIA Waiver by Application). Certification of the laboratories themselves is handled by CMS, while the FDA's role is categorising tests and issuing related rules and guidance (CMS's description)Sourced
Home use and OTCFor blood glucose meters there are separate guidance documents on the studies to include in a 510(k): one for OTC (home) use and one for prescription point-of-care use (both final versions of September 2020, replacing the 2016 versions). For iCGMs, OTC product codes (SAF and SBH) exist for people who do not use insulinSourced
Recognised standardsUnder section 514(c) of the FD&C Act the FDA "recognises" private-sector standards, and manufacturers can use a declaration of conformity to meet submission requirements. The guidance states that using standards is not mandatory in premarket submissions unless a standard has been incorporated into regulation. For CGMs, CLSI POCT05 2nd edition (performance metrics for continuous interstitial glucose monitoring) is recognised as number 7-307, and IEEE/ISO 11073-10425 (CGM device communication) is also on the listSourced
Quality systems21 CFR 820 (the QMSR) was amended to incorporate ISO 13485 by reference as the quality system standard. It was published on 2 February 2024 and took effect on 2 February 2026Sourced
Wellness productsThe General Wellness guidance (6 January 2026, replacing the 2019 version) says CDRH does not intend to examine low-risk products meant only for general wellness to see whether they are devices or meet premarket requirements, under stated conditions including being non-invasive (the guidance is non-binding). Blood glucose meters and CGMs are named as examples of products for medical purposes and fall outside it. Products whose outputs prompt clinical action are also outside itSourced
Laboratory developed tests (LDTs)In May 2024 the FDA issued a rule treating LDTs as in vitro diagnostic products. On 31 March 2025 a federal district court vacated the rule, and in September 2025 the FDA restored the earlier regulatory textSourced
Fees (FY2026)Standard 510(k) fee US$26,067 (US$6,517 for small businesses), De Novo US$173,782, PMA US$579,272Sourced
A caution on reading the counts

FDA review counts change depending on how they are tallied. The annual report says CDRH "received 21,780 medical device submissions" in 2025, which covers many types of submission beyond 510(k) and does not state whether it is a fiscal or calendar year. Counting 510(k) decisions dated 2025 in the FDA's openFDA database (updated 21 September 2026) gives 3,225, of which 54 were in the clinical chemistry review panel (which includes glucose meters), and the panels related to in vitro diagnostics (clinical chemistry, microbiology, haematology, clinical toxicology, immunology and pathology) total 256 (about 7.9%) Our calculation. A review panel is an assignment in the classification system, not a formal marker of an in vitro diagnostic, and openFDA warns that its data are unvalidated.

4. How far its influence reaches (powers and geography)

AspectWhat the FDA hasWhat it does not have
PowersReview and decision before a device is marketed in the U.S. (510(k), De Novo, PMA). An applicant may not market a device until it receives an order of substantial equivalence. Establishment registration and device listing, the quality system regulation (21 CFR 820), and procedures for complaint reporting and advisory notices (21 CFR 803 and 806)The power to write private-sector standards (the FDA only recognises them). The power to make guidance legally binding (guidance is labelled as recommendations). Deciding how a device is used in clinical practice
GeographyDevices imported or sold in the United States. Overseas manufacturing sites must also register and designate a U.S. agentWhether a device may be sold in Japan, the EU or elsewhere, and other regulators' decisions (CDRH takes part in the IMDRF and MDSAP, but each country decides for itself)
CompulsionPremarket review is a condition of sale for devices that require itUse of standards is voluntary unless a standard has been incorporated into regulation. A declaration of conformity is one option
ScaleCDRH annual report: 264,670 regulated medical devices, 21,780 submissions, 25,530 registered firms and 124 novel devices authorised (2025). FDA-wide: 19,687 FTE (FY2024)CDRH's total headcount and counts for in vitro diagnostics alone could not be confirmed in official documents
Review fundingCDRH's full-time equivalents (FTE) devoted to the MDUFA programme total about 1,719 in FY2025: about 1,338 funded by user fees and about 382 by budget appropriationsThe power to set MDUFA (the framework of fees and review goals) on its own. MDUFA is reauthorised by Congress every five years after negotiation with industry

Note: the FTE figures are our sum of the CDRH office values in Table E-2 of the MDUFA performance report Our calculation. The table covers FTEs tied to the MDUFA programme, not CDRH's headcount. The review goals above are those agreed under MDUFA V.

5. Companies and organisations involved

The companies that appear in FDA records do so as applicants to the FDA. The figure below places CGM records found in FDA's databases onto the three pathways.

FDA's three premarket pathways, with CGM examples The pathway depends on whether a predicate exists and on risk. Examples are records in FDA's databases New device (medical or IVD) Needs premarket review before U.S. sale 510(k) Equivalent to a predicate Result: cleared De Novo No predicate, low-moderate risk Result: granted PMA Class III (high risk) Result: approval Goal: 95% decided in 90 FDA days Goal: 70-90% in 150 FDA days Goal: 90% in 180 FDA days Example record Stelo (Dexcom) K234070 5 March 2024 OTC iCGM Example record Dexcom G6 (Dexcom) DEN170088 27 March 2018 Classified under 21 CFR 862.1355 Example record Eversense (Senseonics) P160048 21 June 2018 Implantable CGM FDA days = calendar days under FDA review. Goals are agreed MDUFA V targets, not obligations Example records show review outcomes, not which product is better
Fig. 2 FDA's three premarket pathways, with CGM examples. Sources: the FDA's 510(k), De Novo and PMA pages, the FY2025 MDUFA performance report and the FDA's 510(k), De Novo and PMA databases. The mapping to pathways and the choice of examples are ours and do not endorse any product Our calculation.
OrganisationRelationship with the FDA (what primary sources confirm)Category
Dexcom, Abbott, SenseonicsApplicants in FDA's databases. Dexcom: Dexcom G6 (De Novo) and Stelo (510(k)). Abbott: FreeStyle Libre 3 (K212132, found substantially equivalent on 26 May 2022) and Lingo (K233655, 29 May 2024). Senseonics: Eversense (PMA). Our company profiles in this series cover these firms individuallySourced
CLSI (Clinical and Laboratory Standards Institute)The FDA lists CLSI's POCT05 2nd edition, among others, as a recognised standard. CLSI writes the standard; the FDA recognises itSourced
ISO and IEEEThe QMSR incorporates ISO 13485 by reference. ISO/IEEE 11073-10425 (CGM device communication) and others are on the recognised listSourced
CMS (Centers for Medicare & Medicaid Services)Manages the certification of laboratories under CLIA. The FDA categorises tests by complexity (CMS's description)Sourced
IMDRF and MDSAPAn international forum of regulators and an audit programme usable in several countries, in which CDRH takes part. The annual report says IMDRF membership grew to include 7 new regions in 2025Sourced

6. Outlook

What the evidence suggestsPrimary information it rests onCategory
Quality system requirements have been built on ISO 13485 since 2 February 202621 CFR 820 (QMSR), published 2 February 2024 and effective 2 February 2026. CDRH put implementing the QMSR first on its 2026 planSourced
The framework of review goals and fees (MDUFA V) runs through fiscal 2027. Negotiations for the next one (MDUFA VI) began in 2025The MDUFA performance report gives MDUFA V as FY2023 to FY2027. The CDRH annual report says MDUFA VI negotiations began in 2025. We could not confirm what the new terms will beNot yet confirmed
The share of CDRH's MDUFA-related FTEs funded by user fees rose from 71.9% (FY2024) to 77.8% (FY2025). FTEs funded by budget appropriations fell from about 487 to about 382Our sum of Table E-2 of the MDUFA performance report. The annual report lists "adapting to staffing changes" among its 2026 aimsOur calculation
Review capacity looks set to depend more heavily on user fees and the agreed review goalsThe change in share above. The reports' figures do not show what this means for review quality or durationInference
There were 7 510(k) decisions for OTC iCGMs (product codes SAF and SBH) between March 2024 and August 2026 (Dexcom 4, Abbott 2, Signos 1; two of them Special 510(k)s)Our tally from the openFDA 510(k) API (updated 21 September 2026)Our calculation
Submissions for home and retail CGMs are likely to continueThe count above. This is our reading of the run of SAF and SBH decisions since March 2024; no future filings are publishedInference
Whether a non-invasive sensor's blood glucose estimate can be treated as a general wellness product depends on its claims and outputs and cannot be settled in generalThe conditions in the General Wellness guidance (6 January 2026). Blood glucose meters and CGMs are named as medical-purpose examples, and one example says a product with microneedles that penetrate the skin is not a low-risk wellness productInference
The FDA's policy on regulating LDTs has been halted by a court decision in 2025. We could not confirm what the FDA will do nextThe Federal Register notice of 19 September 2025 records only the restoration of the earlier textNot yet confirmed

7. Glossary

CDRH
The FDA's Center for Devices and Radiological Health. It runs premarket review and postmarket oversight of medical devices.
510(k)
A notification showing a device is substantially equivalent to a legally marketed predicate. The FDA's decision is called "cleared".
De Novo
A route for new types of low- to moderate-risk device with no predicate, creating a new classification. The outcome is "granted".
PMA
Premarket approval, required for the highest-risk Class III devices. The outcome is "approval".
Special controls
Device-specific requirements for Class II devices, on top of general controls, such as the accuracy conditions for iCGMs.
Recognised standard
A private-sector standard the FDA has formally accepted. Manufacturers may declare conformity to it, but using it is generally voluntary.
MDUFA
The Medical Device User Fee Amendments: the framework of submission fees and review goals that Congress renews every five years.
CLIA
The U.S. law on clinical laboratory quality. The FDA categorises tests by complexity; CMS certifies laboratories.
QMSR
The FDA's Quality Management System Regulation, amended to incorporate ISO 13485 and effective 2 February 2026.

8. References

  1. FDA CDRH Annual Report 2025: submissions, regulated devices, registered firms, novel devices authorised, MDUFA V review goals, 2026 plans and international activity. https://www.fda.gov/media/190779/download
  2. FDA Performance Report to Congress, Medical Device User Fee Amendments, FY 2025: the MDUFA V period, the definition of "FDA days" and Table E-2 (CDRH FTEs by office). https://www.fda.gov/media/191127/download
  3. FDA Overview of Device Regulation: Classes I, II and III and the premarket pathways. Updated 30 January 2026. https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/overview-device-regulation
  4. FDA Premarket Notification 510(k): substantial equivalence and "cleared". Current as of 22 August 2024. https://www.fda.gov/medical-devices/premarket-submissions-selecting-and-preparing-correct-submission/premarket-notification-510k
  5. FDA De Novo Classification Request: devices with no predicate at low to moderate risk, and "grants". Current as of 30 September 2025. https://www.fda.gov/medical-devices/premarket-submissions-selecting-and-preparing-correct-submission/de-novo-classification-request
  6. FDA Premarket Approval (PMA): Class III devices and "approval". Current as of 16 May 2019. https://www.fda.gov/medical-devices/premarket-submissions-selecting-and-preparing-correct-submission/premarket-approval-pma
  7. Electronic Code of Federal Regulations 21 CFR 862.1355, Integrated continuous glucose monitoring system: definition of the iCGM, Class II and the special controls. https://www.ecfr.gov/current/title-21/section-862.1355
  8. Electronic Code of Federal Regulations 21 CFR Part 807: sections 807.20 and 807.40 (registration, and U.S. agents for foreign establishments), 807.81 (when a premarket notification is required) and 807.100 (FDA action). https://www.ecfr.gov/current/title-21/part-807
  9. Electronic Code of Federal Regulations 21 CFR Part 820: section 820.10 (ISO 13485 incorporated by reference) and the Quality Management System Regulation (QMSR). https://www.ecfr.gov/current/title-21/part-820
  10. FDA De Novo database, DEN170088 (Dexcom G6; received 8 December 2017, granted 27 March 2018; 21 CFR 862.1355). https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/denovo.cfm?id=DEN170088
  11. FDA 510(k) database, K234070 (Stelo Glucose Biosensor System, Dexcom, 5 March 2024, product code SAF). https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K234070
  12. FDA PMA database, P160048 (Eversense CGM, Senseonics, approved 21 June 2018). https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P160048
  13. FDA (openFDA) openFDA Device 510(k) API: tallies by decision date, review panel and product code (data updated 21 September 2026), including the records for FreeStyle Libre 3, Lingo and the OTC iCGM product codes SAF and SBH. https://open.fda.gov/apis/device/510k/
  14. FDA Recognized Consensus Standards: Medical Devices (CLSI POCT05 2nd edition, recognition number 7-307; IEEE/ISO 11073-10425 and others). https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfStandards/search.cfm
  15. FDA Appropriate Use of Voluntary Consensus Standards in Premarket Submissions for Medical Devices (14 September 2018): section 514(c), declarations of conformity, and standards not being mandatory in general. https://www.fda.gov/media/71983/download
  16. FDA Self-Monitoring Blood Glucose Test Systems for Over-the-Counter Use, final guidance (September 2020). https://www.fda.gov/regulatory-information/search-fda-guidance-documents/self-monitoring-blood-glucose-test-systems-over-counter-use
  17. FDA Blood Glucose Monitoring Test Systems for Prescription Point-of-Care Use, final guidance (September 2020). https://www.fda.gov/regulatory-information/search-fda-guidance-documents/blood-glucose-monitoring-test-systems-prescription-point-care-use
  18. FDA General Wellness: Policy for Low Risk Devices (6 January 2026; replaces the version of 27 September 2019). https://www.fda.gov/media/90652/download
  19. Federal Register Medical Devices; Quality System Regulation Amendments (89 FR 7496, published 2 February 2024, effective 2 February 2026). https://www.federalregister.gov/documents/2024/02/02/2024-01709/medical-devices-quality-system-regulation-amendments
  20. Federal Register Medical Devices; Laboratory Developed Tests (89 FR 37286, 6 May 2024). https://www.federalregister.gov/documents/2024/05/06/2024-08935/medical-devices-laboratory-developed-tests
  21. Federal Register Medical Devices; Laboratory Developed Tests; Implementation of Vacatur (90 FR 45134, 19 September 2025), reflecting the district court's order of 31 March 2025. https://www.federalregister.gov/documents/2025/09/19/2025-18239/regulation-identification-number-0910-aj05-medical-devices-laboratory-developed-tests-implementation
  22. Federal Register Medical Device User Fee Rates for Fiscal Year 2026 (30 July 2025): FY2026 fees and FDA-wide FTE. https://www.federalregister.gov/documents/2025/07/30/2025-14412/medical-device-user-fee-rates-for-fiscal-year-2026
  23. FDA OHT7: Office of In Vitro Diagnostics: the office and its divisions. Updated 21 September 2022. https://www.fda.gov/about-fda/cdrh-offices/oht7-office-in-vitro-diagnostics-office-product-evaluation-and-quality
  24. FDA CLIA Categorizations: test categories and the CLIA Waiver by Application. Current as of 17 July 2023. https://www.fda.gov/medical-devices/ivd-regulatory-assistance/clia-categorizations
  25. CMS Understanding CLIA Certification, Accreditation & Test Complexity: the roles of the FDA and CMS. Page dated 31 August 2026. https://www.cms.gov/medicare/health-safety-standards/clinical-laboratory-improvement-amendments-clia/getting-started-clia/understanding-clia-certification-accreditation-test-complexity
  26. FDA About CDRH: its mission and position. Updated 10 September 2026. https://www.fda.gov/about-fda/fda-organization/center-devices-and-radiological-health

9. Claim-to-source audit

Claim in the articleCategorySource
The CDRH mission and position, membership of HHS, and the FDA's locationSourcedReference 26 https://www.fda.gov/about-fda/fda-organization/center-devices-and-radiological-health
Reference 19 https://www.federalregister.gov/documents/2024/02/02/2024-01709/medical-devices-quality-system-regulation-amendments
Reference 10 https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/denovo.cfm?id=DEN170088
Classes I, II and III, the 510(k), De Novo and PMA pathways and their terms (cleared, granted, approval)SourcedReference 3 https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/overview-device-regulation
Reference 4 https://www.fda.gov/medical-devices/premarket-submissions-selecting-and-preparing-correct-submission/premarket-notification-510k
Reference 5 https://www.fda.gov/medical-devices/premarket-submissions-selecting-and-preparing-correct-submission/de-novo-classification-request
Reference 6 https://www.fda.gov/medical-devices/premarket-submissions-selecting-and-preparing-correct-submission/premarket-approval-pma
Review goals (510(k) 95% in 90 FDA days, De Novo 70 to 90% in 150 FDA days, PMA 90% in 180 FDA days), the MDUFA V period (FY2023 to FY2027) and the definition of FDA daysSourcedReference 1 https://www.fda.gov/media/190779/download
Reference 2 https://www.fda.gov/media/191127/download
No marketing until an order of substantial equivalence; registration and U.S. agent for foreign sites; when a premarket notification is requiredSourcedReference 8 https://www.ecfr.gov/current/title-21/part-807
21,780 submissions, 264,670 regulated devices, 25,530 registered firms, 124 novel devices authorised (2025) and CDRH's "more than 40 years"SourcedReference 1 https://www.fda.gov/media/190779/download
FDA-wide 19,687 FTE (FY2024) and the FY2026 fees (510(k) US$26,067, small business US$6,517, De Novo US$173,782, PMA US$579,272)SourcedReference 22 https://www.federalregister.gov/documents/2025/07/30/2025-14412/medical-device-user-fee-rates-for-fiscal-year-2026
The iCGM definition, Class II and the special controls (accuracy thresholds, consistency over wear, interferents, sensor-life controls)SourcedReference 7 https://www.ecfr.gov/current/title-21/section-862.1355
Stelo (K234070): substantial equivalence and product code SAFSourcedReference 11 https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K234070
Reference 13 https://open.fda.gov/apis/device/510k/
Dexcom G6 (DEN170088): De Novo granted, classification 21 CFR 862.1355SourcedReference 10 https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/denovo.cfm?id=DEN170088
Eversense (P160048): PMA approvalSourcedReference 12 https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P160048
FreeStyle Libre 3 (K212132), Lingo (K233655) and the OTC iCGM product codes SAF and SBHSourcedReference 13 https://open.fda.gov/apis/device/510k/
The Office of In Vitro Diagnostics (OHT7) and the Division of Chemistry and Toxicology DevicesSourcedReference 23 https://www.fda.gov/about-fda/cdrh-offices/oht7-office-in-vitro-diagnostics-office-product-evaluation-and-quality
CLIA test categories, the Waiver by Application, and laboratory certification by CMSSourcedReference 24 https://www.fda.gov/medical-devices/ivd-regulatory-assistance/clia-categorizations
Reference 25 https://www.cms.gov/medicare/health-safety-standards/clinical-laboratory-improvement-amendments-clia/getting-started-clia/understanding-clia-certification-accreditation-test-complexity
The OTC and prescription point-of-care blood glucose guidance documents (final, September 2020, replacing the 2016 versions)SourcedReference 16 https://www.fda.gov/regulatory-information/search-fda-guidance-documents/self-monitoring-blood-glucose-test-systems-over-counter-use
Reference 17 https://www.fda.gov/regulatory-information/search-fda-guidance-documents/blood-glucose-monitoring-test-systems-prescription-point-care-use
How recognised standards work (section 514(c), declaration of conformity, use generally voluntary)SourcedReference 15 https://www.fda.gov/media/71983/download
CLSI POCT05 2nd edition (recognition number 7-307) and IEEE/ISO 11073-10425 as recognised standardsSourcedReference 14 https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfStandards/search.cfm
The QMSR incorporating ISO 13485, published 2 February 2024 and effective 2 February 2026SourcedReference 19 https://www.federalregister.gov/documents/2024/02/02/2024-01709/medical-devices-quality-system-regulation-amendments
Reference 9 https://www.ecfr.gov/current/title-21/part-820
The General Wellness guidance (6 January 2026) and glucose meters and CGMs as outside examplesSourcedReference 18 https://www.fda.gov/media/90652/download
The LDT rule (May 2024), its vacatur on 31 March 2025 and the restoration of 19 September 2025SourcedReference 20 https://www.federalregister.gov/documents/2024/05/06/2024-08935/medical-devices-laboratory-developed-tests
Reference 21 https://www.federalregister.gov/documents/2025/09/19/2025-18239/regulation-identification-number-0910-aj05-medical-devices-laboratory-developed-tests-implementation
CDRH's IMDRF and MDSAP participation and its 2026 plans (QMSR, adapting to staffing changes)SourcedReference 1 https://www.fda.gov/media/190779/download
CDRH's MDUFA-related FTE in FY2025 (about 1,719 in total: about 1,338 fee-funded, about 382 appropriations-funded) and the fee-funded shareOur calculationReference 2 https://www.fda.gov/media/191127/download
510(k) decisions dated 2025 in openFDA: 3,225 in total, 54 in the clinical chemistry panel, 256 (about 7.9%) across the IVD-related panelsOur calculationReference 13 https://open.fda.gov/apis/device/510k/
Seven 510(k) decisions for OTC iCGMs (SAF and SBH) between March 2024 and August 2026Our calculationReference 13 https://open.fda.gov/apis/device/510k/
The four types of institution, and the mapping and choice of examples in Fig. 2Our calculationOur own classification
The FDA's future policy on regulating LDTs after the vacaturNot yet confirmedNot stated in the references; this article does not estimate it
The content of MDUFA VI (fees and review goals)Not yet confirmedNot stated in the references; this article does not estimate it
The inferences in section 6InferenceThis article's reading of references 1, 2, 13, 19, 21 and 22

Last updated 3 October 2026 / Troy Technical
All figures come from official documents of the FDA and CDRH, the Code of Federal Regulations, the Federal Register and the FDA's databases. Items marked "Inference" are this article's reading of the primary information. Nothing here is advice on how to use any product or on any reader's personal health.

🌐 Japanese