Researchers found that copper adhesion to implanted polyimide varies by more than tenfold despite nearly identical surface energies. Carbon/nitrogen co-implantation achieved the highest peel strength of 1.63 N/mm, demonstrating that chemical reconstruction, not just wettability or roughness, governs interfacial bonding.
In Depth

Key Findings

Copper films deposited on polyimide exhibit wildly different adhesion strengths even when surface energies are matched within a narrow band of 46.43 to 47.22 mJ/m². The strongest adhesion was achieved via carbon and nitrogen co-implantation, yielding a peel strength of 1.63 N/mm. This is approximately 11.6 times the adhesion of carbon-implanted surfaces (0.14 N/mm) and 8.2 times that of nitrogen-implanted surfaces (0.20 N/mm). Untreated polyimide showed the lowest adhesion at 0.06 N/mm.

Technical Details

The study compared four conditions using 25-micrometer polyimide films: untreated, carbon-ion implanted (20 keV), nitrogen-ion implanted (25 keV), and co-implanted with carbon (15 keV) and nitrogen (8 keV), all at fluences of 5 × 10^15 ions/cm². Copper films of 2 micrometers were deposited via DC magnetron sputtering and electroplated to 18 micrometers for testing per IPC-TM-650 2.4.9 E.

  • Electrical Performance: Sheet resistance varied slightly, with nitrogen-implanted films showing the lowest resistance (14 mΩ/sq) compared to co-implanted (17 mΩ/sq) and carbon-implanted (20 mΩ/sq) films.
  • Morphology: AFM revealed root-mean-square roughness rose from 1.90 nm (untreated) to 5.34 nm (co-implanted). However, carbon-implanted surfaces (4.61 nm) remained weak despite high roughness.
  • Chemistry: XPS showed nitrogen implantation caused substantial degradation of imide structures and a rise in surface carbon (94.09 atomic %). Co-implantation retained elemental concentrations closer to untreated polyimide, including 5.52 atomic % oxygen.

Background & Context

Reliable metallization of polymer substrates is critical for flexible electronics and high-frequency systems. Previous plasma processing studies often altered roughness, surface energy, and chemical functionality simultaneously. By tuning ion energy and fluence to match surface energies, researchers neutralized wettability as a variable to isolate the factors controlling adhesion.

Significance & Outlook

The results indicate that interfacial adhesion and electrical continuity are associated with different reconstructed surface states and should be treated as decoupled optimization targets. The findings suggest that nanoscale roughness is a contributing but non-sufficient condition for strong bonding.

Source: https://bioengineer.org/matched-surface-energies-wildly-different-copper-adhesion-on-implanted-polyimide/

Get our weekly technology intelligence — free

Receive an infographic that lets you judge at a glance whether each field’s analysis report is worth reading.

Subscribe Free — Weekly Tech Intelligence

By subscribing, you’ll receive Troy-Technical’s weekly technology intelligence newsletter.

  • Your email and selected fields are used only to deliver the newsletter.
  • We never share your information with third parties.
  • You can unsubscribe anytime via the link in each email.

See our Privacy Policy for details.

Takes about a minute · Unsubscribe anytime

Published by Troy-Technical, an independent site run by one engineer with a career in materials development.
About the author / Contact info@troy-technical.jp
Let's share this post !

Author of this article

TOC